Related Experiment Video
Updated: Jul 31, 2025

Author Spotlight: Developing a Disposable Dosator for Preclinical Testing of Dry Powder Inhalers in Small Animal Models
Published on: August 18, 2023
Closed System Transfer Devices (CSTDs): Understanding Potential Over- and Under- Dosing of Liquid Vial Drug Products
Christian Lehermayr1, Bernhard Schmelzer2, Maximilian Kropf2
1Biologics Analytical Development, Novartis Pharma, Langkampfen, Austria.
Abstract:
Closed system transfer devices (CSTDs) are a major challenge for drug manufacturers to assess and assure drug compatibility and acceptable dosing accuracy for a range of clinical administration strategies. In this article, we systematically investigate parameters affecting the loss of product during transfer by CSTDs from vials to infusion bags. We show that liquid volume loss increases with vial size, vial neck diameter, and solution viscosity - while dependent on stopper design. We further compared CSTDs' performance with a traditional syringe transfer and learned that loss is larger for CSTDs than for syringe transfer. Based on experimental data, a statistical model was developed to predict drug loss upon transfer by CSTDs. The model predicted that, for single dose vials with USP<1151> conforming overfill, a complete extraction and transfer of the full dose can be assured for a broad range of CSTDs, product viscosities, and vial types (2R, 6R, 10R, 20R) if a flush (of syringe, syringe adaptor, bag spike) is performed. The model also predicted that complete transfer cannot be achieved for fill volumes ≤ 2.0 mL. For multi-dose vials and pooling of several vials, respectively, the effective dose transfer (i.e., ≥ 95%) for all CSTDs tested was predicted to be achieved if a minimum of 5.0 mL is transferred.
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...
Drug Distribution: Volume of Distribution

