Membrane-based microfluidic solvent extraction of Ga-68 from aqueous Zn solutions: towards an automated cyclotron production loop
Related Experiment Video
Updated: Jul 31, 2025

Author Spotlight: Advancing Therapeutics with Biocompatible Sodium Alginate Hydrogel Microspheres
Published on: June 7, 2024
Svenja Trapp1, Tom Lammers1, Gokce Engudar2
1Department of Radiation Science and Technology, Reactor Institute Delft, Delft University of Technology, Mekelweg 15, 2629 JB, Delft, The Netherlands.
Background:
The radionuclide Ga-68 is commonly used in nuclear medicine, specifically in positron emission tomography (PET). Recently, the interest in producing Ga-68 by cyclotron irradiation of [68Zn]Zn nitrate liquid targets is increasing. However, current purification methods of Ga-68 from the target solution consist of multi-step procedures, thus, leading to a significant loss of activity through natural decay. Additionally, several processing steps are needed to recycle the costly, enriched target material.
Results:
To eventually allow switching from batch to continuous production, conventional batch extraction and membrane-based microfluidic extraction were compared. In both approaches, Ga-68 was extracted using N-benzoyl-N-phenylhydroxylamine in chloroform as the organic extracting phase. Extraction efficiencies of up to 99.5% ± 0.6% were achieved within 10 min, using the batch approach. Back-extraction of Ga-68 into 2 M HCl was accomplished within 1 min with efficiencies of up to 94.5% ± 0.6%. Membrane-based microfluidic extraction achieved 99.2% ± 0.3% extraction efficiency and 95.8% ± 0.8% back-extraction efficiency into 6 M HCl. When executed on a solution irradiated with a 13 MeV cyclotron at TRIUMF, Canada, comparable efficiencies of 97.0% ± 0.4% were achieved. Zn contamination in the back-extracted Ga-68 solution was found to be below 3 ppm.
Conclusions:
Microfluidic solvent extraction is a promising method in the production of Ga-68 achieving high efficiencies in a short amount of time, potentially allowing for direct target recycling.