Spectrometer based on a compact disordered multi-mode interferometer
Optics Express
|May 9, 2023
Summary
We developed a compact, CMOS-compatible photonic integrated circuit spectrometer. This device utilizes a novel design for efficient light dispersion and analysis, offering high resolution for various applications.
Area of Science:
- Photonics and optical engineering
- Integrated optics
- Spectroscopy
Background:
- Photonic integrated circuits (PICs) offer miniaturization and scalability for optical systems.
- Spectrometers are crucial for wavelength analysis across scientific and industrial fields.
- Silicon-on-insulator (SOI) technology enables advanced photonic device fabrication.
Purpose of the Study:
- To present a compact, CMOS-compatible photonic integrated circuit (PIC) based spectrometer.
- To demonstrate a novel spectrometer design integrating a dispersive array element with a multimode interferometer (MMI).
- To characterize the performance of the fabricated spectrometer at the 1310 nm wavelength.
Main Methods:
- Fabrication of a spectrometer on the silicon-on-insulator (SOI) platform.
- Integration of a dispersive array element comprising SiO2-filled scattering holes within an MMI.
- Characterization of the spectrometer's bandwidth and resolution around 1310 nm.
Main Results:
- The developed spectrometer is compact and CMOS compatible.
- The device integrates a dispersive array of SiO2-filled scattering holes within an MMI.
- The spectrometer exhibits a 67 nm bandwidth, a 1 nm lower bandwidth limit, and a 3 nm peak-to-peak resolution at 1310 nm.
Conclusions:
- The presented PIC-based spectrometer offers a promising solution for miniaturized and integrated spectroscopic analysis.
- The novel design combining scattering holes and MMI achieves competitive resolution and bandwidth.
- The CMOS compatibility facilitates potential integration into larger electronic-photonic systems.
Related Concept Videos
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
265
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
265
Raman Spectroscopy Instrumentation: Overview
475
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
475
Mass Analyzers: Common Types
662
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
662
Tandem Mass Spectrometry
1.1K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.1K
Mass Analyzers: Overview
756
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
756