Related Experiment Video
Updated: Jul 31, 2025

Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
Published on: November 19, 2020
Estimation of optical properties of turbid media using spatially resolved diffuse reflectance combined with
Abstract:
The accurate estimation of the optical properties of turbid media by using a spatially resolved (SR) technique remains a challenging task due to measurement errors in the acquired spatially resolved diffuse reflectance (SRDR) and challenges in inversion model implementation. In this study, what we believe to be a novel data-driven model based on a long short-term memory network and attention mechanism (LSTM-attention network) combined with SRDR is proposed for the accurate estimation of the optical properties of turbid media. The proposed LSTM-attention network divides the SRDR profile into multiple consecutive and partially overlaps sub-intervals by using the sliding window technique, and uses the divided sub-intervals as the input of the LSTM modules. It then introduces an attention mechanism to evaluate the output of each module automatically and form a score coefficient, finally obtaining an accurate estimation of the optical properties. The proposed LSTM-attention network is trained with Monte Carlo (MC) simulation data to overcome the difficulty in preparing training (reference) samples with known optical properties. Experimental results of the MC simulation data showed that the mean relative error (MRE) with 5.59% for the absorption coefficient [with the mean absolute error (MAE) of 0.04 cm-1, coefficient of determination (R2) of 0.9982, and root mean square error (RMSE) of 0.058 cm-1] and 1.18% for the reduced scattering coefficient (with an MAE of 0.208 cm-1, R2 of 0.9996, and RMSE of 0.237 cm-1), which were significantly better than those of the three comparative models. The SRDR profiles of 36 liquid phantoms, collected using a hyperspectral imaging system that covered a wavelength range of 530-900 nm, were used to test the performance of the proposed model further. The results showed that the LSTM-attention model achieved the best performance (with the MRE of 14.89%, MAE of 0.022 cm-1, R2 of 0.9603, and RMSE of 0.026 cm-1 for the absorption coefficient; and the MRE of 9.76%, MAE of 0.732 cm-1, R2 of 0.9701, and RMSE of 1.470 cm-1for the reduced scattering coefficient). Therefore, SRDR combined with the LSTM-attention model provides an effective method for improving the estimation accuracy of the optical properties of turbid media.
More Related Videos
07:06Simultaneous Evaluation of Cerebral Hemodynamics and Light Scattering Properties of the In Vivo Rat Brain Using Multispectral Diffuse Reflectance Imaging
Published on: May 7, 2017
10:35Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
Published on: October 17, 2016