Related Experiment Video
Updated: Jul 31, 2025

A Simple Flow Cytometry Based Assay to Determine In Vitro Antibody Dependent Enhancement of Dengue Virus Using Zika Virus Convalescent Serum
Published on: April 10, 2018
Comparing the performance of dengue virus IgG and IgG-capture enzyme-linked immunosorbent assays in seroprevalence
Jih-Jin Tsai1,2,3, Ching-Yi Tsai1, Ping-Chang Lin1
1Tropical Medicine Center, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.
Background:
Dengue virus (DENV) is the leading cause of arboviral diseases in humans worldwide. Currently Dengvaxia, the first dengue vaccine licensed in 20 countries, was recommended for DENV seropositive individuals aged 9-45 years. Studying dengue seroprevalence can improve our understanding of the epidemiology and transmission dynamics of DENV, and facilitate future intervention strategies and assessment of vaccine efficacy. Several DENV envelope protein-based serological tests including IgG and IgG-capture enzyme-linked immunosorbent assays (ELISAs) have been employed in seroprevalence studies. Previously DENV IgG-capture ELISA was reported to distinguish primary and secondary DENV infections during early convalescence, however, its performance over time and in seroprevalence study remains understudied.
Methods:
In this study, we used well-documented neutralization test- or reverse-transcription-polymerase-chain reaction-confirmed serum/plasma samples including DENV-naïve, primary and secondary DENV, primary West Nile virus, primary Zika virus, and Zika with previous DENV infection panels to compare the performance of three ELISAs.
Results:
The sensitivity of the InBios IgG ELISA was higher than that of InBios IgG-capture and SD IgG-capture ELISAs. The sensitivity of IgG-capture ELISAs was higher for secondary than primary DENV infection panel. Within the secondary DENV infection panel, the sensitivity of InBios IgG-capture ELISA decreased from 77.8% at < 6 months to 41.7% at 1-1.5 years, 28.6% at 2-15 years and 0% at > 20 years (p < 0.001, Cochran-Armitage test for trend), whereas that of IgG ELISA remains 100%. A similar trend was observed for SD IgG-capture ELISA.
Conclusions:
Our findings demonstrate higher sensitivity of DENV IgG ELISA than IgG-capture ELISA in seroprevalence study and interpretation of DENV IgG-capture ELISA should take sampling time and primary or secondary DENV infection into consideration.