Related Experiment Video
Updated: Jul 31, 2025

A Polyaniline-based Sensor of Nucleic Acids
Published on: November 1, 2016
Metal-organic frameworks (MOFs) composite of polyaniline-CNT@aluminum succinate for non-enzymatic nitrite sensor
Amjad E Alsafrani1, Waheed A Adeosun2, Raja Saad Alruwais3
1Department of Chemistry, College of Science, University of Jeddah, Jeddah, 21589, Saudi Arabia.
Abstract:
Nitrite has been linked to a variety of health issues, as well as cancer and oxygen deficiency when its allowable limit is exceeded. Nitrite monitoring and detection are required due to the negative effects on public health. Metal-organic frameworks (MOFs)-based nanomaterials/composites have recently been shown to have the potential for various biological and medical applications like sensing, imaging, and drug delivery. As a result, this research creates an efficient electrochemical sensor by incorporating MOFs into polyaniline (PANI)/carbon nanotube (CNT) cast on the GCE. In situ oxidative polymerization was used to construct an aluminum succinate MOF (Al-Succin)-incorporated CNT/PANI nanocomposite (PANI/CNT@Al-Succin) and well characterized by various characterization techniques, namely, field emission scanning electron microscopy (FE-SEM), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction spectroscopy (XRD), X-ray photoelectron spectroscopy (XPS), thermogravimetric-differential thermal analysis (TGA-DTA), cyclic voltammetry (CV), and four probes to measure DC electrical conductivity. Cyclic voltammetry and linear sweep voltammetry techniques were employed to detect nitrite on the surface of PANI/CNT@Al-Succin-modified glassy carbon electrode (GCE). PANI/CNT@Al-Succin-modified GCE demonstrated good current response and electrocatalytic property towards nitrite compared to bare GCE. The newly synthesized electrode exhibited a high electrocatalytic activity towards nitrite oxidation and showed a linear response ranging from 5.7 to 74.1 μM for CV and 8.55-92.62 μM for LSV. The obtained LOD values for CV (1.16 μM) and LSV (0.08 μM) were significantly below the WHO-defined acceptable nitrite limit in drinking water. Results of recovery studies for real samples of apple juice, orange juice, and bottled water were 98.92%, 99.38%, and 99.90%, respectively. These values show practical usability of PANI/CNT@Al-Succin in real samples.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
06:45Author Spotlight: Characterizing Porous Materials for Aiding the Development of Robust Metal-Organic Frameworks with Adsorption Behavior
Published on: March 8, 2024