Related Experiment Video
Updated: Jul 31, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Wearable Graphene-based smart face mask for Real-Time human respiration monitoring
Hossein Cheraghi Bidsorkhi1,2, Negin Faramarzi1,2, Babar Ali1,2
1Department of Astronautical, Electrical, and Energy Engineering (DIAEE), Sapienza University of Rome, via Eudossiana 18, 00184 Rome, Italy.
Abstract:
After the pandemic of SARS-CoV-2, the use of face-masks is considered the most effective way to prevent the spread of virus-containing respiratory fluid. As the virus targets the lungs directly, causing shortness of breath, continuous respiratory monitoring is crucial for evaluating health status. Therefore, the need for a smart face mask (SFM) capable of wirelessly monitoring human respiration in real-time has gained enormous attention. However, some challenges in developing these devices should be solved to make practical use of them possible. One key issue is to design a wearable SFM that is biocompatible and has fast responsivity for non-invasive and real-time tracking of respiration signals. Herein, we present a cost-effective and straightforward solution to produce innovative SFMs by depositing graphene-based coatings over commercial surgical masks. In particular, graphene nanoplatelets (GNPs) are integrated into a polycaprolactone (PCL) polymeric matrix. The resulting SFMs are characterized morphologically, and their electrical, electromechanical, and sensing properties are fully assessed. The proposed SFM exhibits remarkable durability (greater than1000 cycles) and excellent fast response time (∼42 ms), providing simultaneously normal and abnormal breath signals with clear differentiation. Finally, a developed mobile application monitors the mask wearer's breathing pattern wirelessly and provides alerts without compromising user-friendliness and comfort.
Related Concept Videos
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...