Related Experiment Video
Updated: Jul 31, 2025

An Ex Vivo Tissue Culture Model of Cartilage Remodeling in Bovine Knee Explants
Published on: November 3, 2019
An ultra-sensitive SPR immunosensor for quantitative determination of human cartilage oligomeric matrix protein
Asta Kausaite-Minkstimiene1, Anton Popov1, Ursule Kalvaityte2
1Department of Immunology, State Research Institute Centre for Innovative Medicine, LT-08406, Vilnius, Lithuania; NanoTechnas ‒ Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225, Vilnius, Lithuania.
Abstract:
This paper reports the development of a novel surface plasmon resonance (SPR) immunosensor for ultra-sensitive quantitative determination of human articular cartilage oligomeric matrix protein (COMP), a major component of the extracellular matrix and an exploratory biomarker. Capture antibodies against human COMP (anti-COMP16F12) were covalently immobilized on an 11-mercaptoundecanoic acid (11-MUA) self-assembled monolayer (SAM)-coated SPR sensor disk and a dual sandwich-type signal amplification strategy using biotinylated detection antibodies against COMP (anti-COMP17C10-biot) and streptavidin-conjugated quantum dots (SAv‒QDs) were used for the development of an immunosensor. The binding of high-mass SAv‒QDs via biotin-streptavidin interaction to the surface of the immunosensor resulted in a drastic increase in the sensitivity. The developed immunosensor was able to detect concentrations of COMP in a range from 2.80 to 680.54 fM with a limit of detection (LOD) and a limit of quantification (LOQ) of 0.15 and 0.50 fM, respectively. The immunosensor exhibited good repeatability (relative standard deviation (RSD) 8.05%) and reproducibility (RSD 9.88%) as well as excellent operational stability (2.14 % decrease in SPR signal after 13 days). In addition, the analysis of secretomes of human knee articular cartilage explants from patients with osteoarthritis revealed that the immunosensor has good accuracy (analytical error less than 5 %). These results indicate that the immunosensor developed may be suitable for quantitative determination of COMP derived from articular cartilage and other synovial joint tissues in clinical studies.
More Related Videos
09:08Biotribological Testing and Analysis of Articular Cartilage Sliding against Metal for Implants
Published on: May 14, 2020
08:26Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018