Related Experiment Video
Updated: Jul 30, 2025

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
Published on: February 3, 2014
Effects of vocal fold lesions on particle deposition in a mouth-throat model: A numerical study
Pengcheng Yu1, Chao Xue1, Jonah Rosenthal2
11st Department of Otolaryngology, Eye Ear Nose & Throat Hospital, Fudan University, 200031 Shanghai, China.
Objective:
Dysphonia is very common worldwide and aerosol drug inhalation is an important treatment for patients with dysphonia. This study aimed to explore the effects of vocal fold (VF) lesions on the particle deposition pattern using computational modeling.
Methods:
A realistic mouth-throat (MT) model of a healthy adult was constructed based on computed tomography images. Small and large vocal fold lesions were incorporated in the original model. A steady inhalation flowrate of 15 and 30 liter per minute (LPM) was used as the velocity inlet and monodisperse particles with diameters of 5 to 10 µm were simulated.
Results:
Particles of larger size are more likely to be deposited in MT models, most of them distributed in oral cavity, oropharynx and supraglottis. The ideal sizes at 30 LPM ranged over 7-10 µm for healthy VFs and 6-8 µm for VF lesions. The best sizes at 15 LPM ranged over 6-8 µm for healthy VFs and 8-9 µm for VF lesions.
Conclusion:
Based on this study, VF lesions influence the deposition pattern in the glottis obviously. The ideal sizes differ at the flow rates of 15 and 30 LPM.