Related Experiment Video
Updated: Jul 30, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
OLD-TAVR score to predict 2-year mortality in patients aged 75 years and more undergoing transcatheter aortic valve
Christophe de Terwangne1, Frédéric Maes2,3, Isabelle Gilard4
1Geriatric Medicine, Cliniques Universitaires Saint-Luc - Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels, Belgium. Christophe.deterwangne@saintluc.uclouvain.be.
Purpose:
Decision-making on transcatheter aortic valve replacement (TAVR) in patients aged 75 years and older is complex. It could be facilitated by the identification of predictors of long-term mortality. This study aimed to identify predictors of 2-year mortality to develop a 2-year mortality risk score.
Methods:
Cohort study of consecutive patients aged ≥ 75 years who underwent TAVR after a comprehensive geriatric assessment (CGA) at our university hospital between 2012 and 2019. Predictors of 2-year mortality were determined using multivariable Cox regression. A point-based predictive model was developed based on risk factors and subsequently internally validated by fivefold cross-validation.
Results:
The 345 patients (median age 87 years, 54% women) were fit/vulnerable (32%), mildly frail (37%), or moderately/severely frail (31%). The overall 2-year mortality rate was 26%, predicted by atrial fibrillation, hemoglobin ≤ 10 g/dL, age ≥ 87 years, BMI ≤ 24, eGFR ≤ 50 ml/min, and moderate/severe frailty. The risk score (range 0-12), named OLD-TAVR score, for 2-year mortality showed good discriminative power (AUC 0.70) and remained consistent after fivefold cross-validation (cvAUC 0.69). A risk score ≥ 8 (prevalence 20%) predicted a 45% (95%CI: 34-58%) two-year mortality, with high specificity (86%) and good positive predictive power (+ LR 2.43).
Conclusion:
A 2-year mortality risk score (OLD-TAVR score) for very old patients undergoing TAVR was developed based on six bio-clinical items. A score ≥ 8 identified patients in whom 2-year mortality was very high and thereby the TAVR futile.
Trial Registration Number And Date Of Registration:
Study protocol B403, 26/09/2022, retrospectively registered.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Mitral Valve Prolapse II: Assessment and Management
Aortic Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Actuarial Approach
Consider the example of a high-risk surgical procedure with significant early-stage mortality. A two-year clinical study is conducted,...
Mitral Stenosis III: Medical Management