Related Experiment Video
Updated: Jul 30, 2025

Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
Co-administration of Intravenous Drugs: Rapidly Troubleshooting the Solid Form Composition of a Precipitate in a
Niklas Nilsson1,2, Katerina Nezvalova-Henriksen1,2, Johan P Bøtker3
1Department of Pharmacy, University of Oslo, Oslo 0316, Norway.
Abstract:
Intravenous drugs are often co-administrated in the same intravenous catheter line due to which compatibility issues, such as complex precipitation processes in the catheter line, may occur. A well-known example that led to several neonatal deaths is the precipitation due to co-administration of ceftriaxone- and calcium-containing solutions. The current study is exploring the applicability of Raman spectroscopy for testing intravenous drug compatibility in hospital settings. The precipitation of ceftriaxone calcium was used as a model system and explored in several multi-drug mixtures containing both structurally similar and clinically relevant drugs for co-infusion. Equal molar concentrations of solutions containing ceftriaxone and calcium chloride dihydrate were mixed with solutions of cefotaxime, ampicillin, paracetamol, and metoclopramide. The precipitate formed was collected as an "unknown" material, dried, and analyzed. Several solid-state analytical methods, including X-ray powder diffraction, Raman spectroscopy, and thermogravimetric analysis, were used to characterize the precipitate. Raman microscopy was used to investigate the identity of single sub-visual particles precipitated from a mixture of ceftriaxone, cefotaxime, and calcium chloride. X-ray powder diffraction suggested that the precipitate was partially crystalline; however, the identity of the solid form of the precipitate could not be confirmed with this standard method. Raman spectroscopy combined with multi-variate analyses (principal component analysis and soft independent modelling class analogy) enabled the correct detection and identification of the precipitate as ceftriaxone calcium. Raman microscopy enabled the identification of ceftriaxone calcium single particles of sub-visual size (around 25 μm), which is in the size range that may occlude capillaries. This study indicates that Raman spectroscopy is a promising approach for supporting clinical decisions and especially for compatibility assessments of drug infusions in hospital settings.
More Related Videos
10:31Diffuse Reflectance Infrared Spectroscopic Identification of Dispersant/Particle Bonding Mechanisms in Functional Inks
Published on: May 8, 2015
07:37An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020
Related Concept Videos
Precipitation and Co-precipitation
Washing, Drying, and Ignition of Precipitates
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Precipitation Processes
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gravimetry: Inorganic And Organic Precipitating Agents