Application of an artificial intelligence ensemble for detection of important secondary findings on lung ventilation
Carter Smith1, Sophia Nance1, Jordan H Chamberlin1
1Division of CardioThoracic Radiology, Department of Radiology and Radiological Science, Medical University of South Carolina, 96 Jonathan Lucas Street, Suite 210, MSC 323, Charleston, SC 29425, United States of America.
Rationale:
Single-photon-emission-computerized-tomography/computed-tomography(SPECT/CT) is commonly used for pulmonary disease. Scant work has been done to determine ability of AI for secondary findings using low-dose-CT(LDCT) attenuation correction series of SPECT/CT.
Methods:
120 patients with ventilation-perfusion-SPECT/CT from 9/1/21-5/1/22 were included in this retrospective study. AI-RAD companion(VA10A,Siemens-Healthineers, Erlangen, Germany), an ensemble of deep-convolutional-neural-networks was evaluated for the detection of pulmonary nodules, coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss. Accuracy, sensitivity, specificity was measured for the outcomes. Inter-rater reliability were measured. Inter-rater reliability was measured using the intraclass correlation coefficient (ICC) by comparing the number of nodules identified by the AI to radiologist.
Results:
Overall per-nodule accuracy, sensitivity, and specificity for detection of lung nodules were 0.678(95%CI 0.615-0.732), 0.956(95%CI 0.900-0.985), and 0.456(95%CI 0.376-0.543), respectively, with an intraclass correlation coefficient (ICC) between AI and radiologist of 0.78(95%CI 0.71-0.83). Overall per-patient accuracy for AI detection of coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.939(95%CI 0.878-0.975), 0.974(95%CI 0.925-0.995), and 0.857(95%CI 0.781-0.915), respectively. Sensitivity for coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.898(95%CI 0.778-0.966), 1 (95%CI 0.958-1), and 1 (95%CI 0.961-1), respectively. Specificity for coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.969(95% CI 0.893-0.996), 0.897 (95% CI 0.726-0.978), and 0.346 (95% CI 0.172-0.557), respectively.
Conclusion:
AI ensemble was accurate for coronary artery calcium and aortic ectasia/aneurysm, while sensitive for aortic ectasia/aneurysm, lung nodules and vertebral height loss on LDCT attenuation correction series of SPECT/CT.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies for Cardiovascular System V: CT