Related Experiment Video
Updated: Jul 30, 2025

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Quality assessment of shoulder MRI according to practice parameters of American College of Radiology: A multi-center
Mohammad Ayasrah1, Izzeddin Qtaish2
1Department of Allied Medical Sciences, Jordan University of Science and Technology, Ramtha, Jordan.
Abstract:
Magnetic resonance imaging (MRI) is essential for assessing shoulder conditions. This study aimed to evaluate current shoulder MRI practices in Jordan, including technical parameter patterns, and determine if they adhere to the American College of Radiology (ACR) guidelines. The retrospective analysis included data from 48 eligible participants from 13 MRI centers in March 2021. Descriptive and correlation data analysis were performed using IBM SPSS statistics version_20 and Excel 2013. Most MRI centers (50%) were private outpatient clinics with closed MRI machines above 1 Tesla. Most participants (62.5%) were male, and shoulder pain (47.9%) was the main clinical indication. Most shoulder orientations (68.7%, 33/48) were right shoulders, and the coronal MRI planes (43%, 121/280) were the most common. The alignment percentage for the axial plane was 100%, but MRI artifacts of the shoulder were present in 8.2% of cases (23/280). Dark fluid T1-W coronal sequence was not conducted in 25% of the cases. The percentage of the field view (FOV) within ACR recommendations was 45% (126/281), and slice thickness parameters were 96% (269/281). The recommended pixel area for all sequences was 47.9% (134/280), encompassing all axial, sagittal oblique, and coronal planes. However, crucial parameters, such as FOV and slice thickness, were inadequate and did not meet the ACR guidelines, resulting in suboptimal image quality of shoulder MRI. To improve MRI image quality, it is recommended that MRI technologists receive ongoing education and training on appropriate MRI image parameters.
More Related Videos
08:57Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software
Published on: September 4, 2021
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...