Related Experiment Video
Updated: Jul 30, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Estimated GFR Accuracy When Cystatin C- and Creatinine-Based Estimates Are Discrepant in Older Adults
O Alison Potok1,2, Dena E Rifkin1,2, Joachim H Ix1,2
1Division of Nephrology-Hypertension, University of California San Diego, San Diego, CA.
Rationale & Objective:
Serum creatinine and cystatin C are used to estimate glomerular filtration rate, but creatinine-based estimated glomerular filtration rate (eGFRcr), cystatin C-based estimated glomerular filtration rate (eGFRcys), and combined creatinine- and cystatin C-based estimated glomerular filtration rate (eGFRcr-cys) are often divergent, particularly in older adults. We investigated which estimated glomerular filtration rate (eGFR) was more accurate and less biased compared with measured glomerular filtration rate (mGFR).
Study Design:
A diagnostic test study from the Berlin Initiative Study.
Setting & Participants:
The study population included 657 individuals aged 70 years or older with iohexol plasma clearance (mGFR) and serum creatinine and cystatin C measurements: 567 community-dwelling participants and 90 with a serum creatinine of ≥1.5 mg/dL.
Tests Compared:
We defined 3 groups on the basis of the difference eGFRcys - eGFRcr: whether < -5 mL/min/1.73 m2 (lower eGFRcys), within 5 mL/min/1.73 m2 (reference), or ≥ 5 mL/min/1.73 m2 (lower eGFRcr). eGFRcr, eGFRcys, and eGFRcr-cys were compared to mGFR to assess bias and accuracy.
Outcome:
Median bias (eGFR minus mGFR) with 95% CIs and accuracy (percentage of eGFR values within ±30% of mGFR).
Results:
The mean ± standard deviation age was 78 ± 6 years; the mean eGFRcys, eGFRcr, and eGFRcr-cys were 59 ± 23, 64 ± 20, and 61 ± 22 mL/min/1.73 m2, respectively, and the mean mGFR was 56 ± 19 mL/min. Half of the participants were in the lower eGFRcys group (n=337, 51%). Among them, the median bias for eGFRcys was the lowest (median bias, -2.7; 95% CI, -3.8 to -1.9) compared with the other eGFR equations. Conversely, in the lower eGFRcr group (n=121, 18%), the median bias for eGFRcr was the lowest compared with those for eGFRcys and eGFRcr-cys (2.9; [95% CI, 0.9-4.8] vs 13.8 [95% CI, 11.4-15.6] and 9.5 [95% CI, 7.7-11.0], respectively). Accuracy (percentage of eGFR values within ±30% of mGFR) was 93% for eGFRcr in the lower eGFRcr group and 92% for eGFRcys and 94% for eGFRcr-cys in the lower eGFRcys group.
Limitations:
Untested generalizability in younger populations.
Conclusions:
Among older adults, the lower eGFR between eGFRcys and eGFRcr was a more accurate and less biased estimate of mGFR when comparing the groups.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Serum Studies: Renal Function Tests
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...