Related Experiment Video
Updated: Jul 30, 2025

Stimulation Location Determination using a 3D Digitizer with High-Definition Transcranial Direct Current Stimulation
Published on: December 20, 2019
First Clinical Experiences with the New DICOM Neurophysiology Standard
Clemens Lang1,2, Silvia Winkler3, Johannes Koren1,2
1Department of Neurology, Clinic Hietzing, Vienna, Austria.
Background:
Exchange of EEG data among institutions is complicated due to vendor-specific proprietary EEG file formats. The DICOM standard, which has long been used for storage and exchange of imaging studies, was expanded to store neurophysiology data in 2020.
Objectives:
To implement DICOM as an interoperable and vendor-independent storage format for EEG recordings in the Clinic Hietzing.
Methods:
A pilot implementation for automated conversion of EEG data from a proprietary to standardized DICOM format was developed. Additionally, EEG review based on a central DICOM archive in a DICOM EEG viewer (encevis by AIT) was implemented.
Results:
More than 200 long-term video EEG recordings and over 3000 routine EEGs were archived to the central DICOM archive of the WIGEV.
Conclusion:
Using DICOM as a storage format for EEG data is feasible and leads to a substantial improvement of interoperability and facilitates data exchange between institutions.
More Related Videos
09:33Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging
Published on: November 15, 2024
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017