Experimental Investigation of Seismic Performance of Precast Concrete Wall-Beam-Slab Joints with Overlapping U-Bar Loop Connections
Related Experiment Video
Updated: Jul 30, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Feng Chen1, Zhiwu Yu1, Yalin Yu2
1School of Civil Engineering, National Engineering Research Center of High-Speed Railway Construction Technology, Engineering Technology Research Center for Prefabricated Construction Industrialization of Hunan Province, Central South University, 68 South Shaoshan Road, Tianxin District, Changsha 410075, China.
Abstract:
In the era of energy conservation and environmental protection, as well as the industrialization of buildings, precast concrete (PC) structures have been developed and increasingly applied in construction industries due to their advantages of outstanding workability and ecofriendliness. In order to verify the reliability of overlapping U-bar loop connections and a modified form of these connections, and study the seismic performance of PC wall-beam-slab joints with these connection methods, three full-scale wall-beam-slab joints were designed and tested under low reversed cyclic loading, including one cast-in-place (CIP) specimen and two PC specimens. Based on the test results, the seismic performance of the PC joints was studied by comparing their damage process, hysteretic loops and skeleton curves, load-carrying capacity, ductility, equivalent stiffness, and energy dissipation with those of the CIP joint. After analyzing the experimental results, the following conclusions can be drawn: the overlapping U-bar loop connection and its modified form are effective and reasonable; the specimen with the modified connection form showed slightly better mechanical properties; the failure mode of the PC joints was consistent with that of the CIP joint; and the generation, distribution, and development of cracks in the PC specimens were similar to those in the CIP specimen. In addition, the stiffness of the PC joints was similar to that of the CIP joint, and the load-carrying capacity, ductility, and energy dissipation of the PC joints were better than those of the CIP joint. Moreover, the research in this paper can also provide some guidance for assembling wall-beam-slab joints in PC shear wall structures.
Related Concept Videos
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Prestressed Concrete
Design Example: Joints in Concrete Pavements
Contraction joints are typically formed by sawing a groove into the concrete shortly after it has hardened. This creates a weakened vertical plane, deliberately encouraging cracking at...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Design Example: Distributing Reinforcements in Concrete Sections
Expansion and Contraction in Masonry Walls
To...