Related Experiment Video
Updated: Jul 30, 2025

Three-Dimensional Imaging of Aortic Tissues in Atherosclerosis
Published on: October 25, 2024
Improving image quality and resolution of coronary arteries in coronary computed tomography angiography by using
Yiming Wang1, Geliang Wang1, Xin Huang1
1Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Background:
Coronary computed tomography angiography (CTA) has been increasingly used to identify the degree of coronary artery stenosis and plaque lesions in vessels. This study evaluated the feasibility of using high-definition (HD) scanning with high-level deep learning image reconstruction (DLIR-H) to improve the image quality and spatial resolution when imaging calcified plaques and stents in coronary CTA as compared to the standard definition (SD) reconstruction mode with adaptive statistical iterative reconstruction-V (ASIR-V).
Methods:
A total of 34 patients (age 63.3±10.9 years; 55.88% female) with calcified plaques and/or stents who underwent coronary CTA in HD-mode were included in this study. Images were reconstructed with SD-ASIR-V, HD-ASIR-V, and HD-DLIR-H. Subjective image quality with image noise and clarity of vessels, calcifications, and stented lumens was evaluated by 2 radiologists using a 5-point scale. The kappa (κ) test was used to analyze the interobserver agreement. Objective image quality with image noise, signal-to-noise-ratio (SNR), and contrast-to-noise-ratio (CNR) was measured and compared. Image spatial resolution and beam-hardening artifacts (BHAs) were also evaluated using the calcification diameter and CT numbers in 3 points along the stented lumen (inside, at the proximal and distal ends just outside stent).
Results:
There were 45 calcified plaques and 4 coronary stents. HD-DLIR-H images had the highest overall image quality score (4.50±0.63) with the lowest image noise (22.59±3.59 HU) and the highest SNR (18.30±4.88) and CNR (26.56±6.33), followed by SD-ASIR-V50% image quality score (4.06±2.49), image noise (35.02±8.09 HU), SNR (12.77±1.59), CNR(15.67±1.92) and HD-ASIR-V50% image quality score (3.90±0.64), image noise (57.7±12.03 HU), SNR (8.16±1.86), CNR (10.01±2.39). HD-DLIR-H images also had the smallest calcification diameter measurement (2.36±1.58 mm), followed by HD-ASIR-V50% (3.46±2.07 mm) and SD-ASIR-V50% (4.06±2.49 mm). HD-DLIR-H images had the closest CT value measurements for the 3 points along the stented lumen, indicating much less BHA. Interobserver agreement on the image quality assessment was good to excellent (HD-DLIR-H: κ value =0.783; HD-ASIR-V50%: κ value =0.789; SD-ASIR-V50%: κ value =0.671).
Conclusions:
Coronary CTA with HD scan mode and DLIR-H significantly improves the spatial resolution for displaying calcifications and in-stent lumens while simultaneously reducing image noise.
More Related Videos
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...