Related Experiment Video
Updated: Jul 30, 2025

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Computer-Aided Detection of Subsolid Nodules on Chest Computed Tomography: Assessment of Visualization on
Kotaro Yoshida1, Atsushi Takamatsu1, Fumihito Toshima1
1From the Department of Radiology, Kanazawa University Graduate School of Medical Sciences.
Objectives:
This study aimed to clarify the performance of automatic detection of subsolid nodules by commercially available software on computed tomography (CT) images of various slice thicknesses and compare it with visualization on the accompanying vessel-suppression CT (VS-CT) images.
Methods:
A total of 95 subsolid nodules from 84 CT examinations of 84 patients were included. The reconstructed CT image series of each case with 3-, 2-, and 1-mm slice thicknesses were loaded into a commercially available software application (ClearRead CT) for automatic detection of subsolid nodules and generation of VS-CT images. Automatic nodule detection sensitivity was assessed for 95 nodules on each series of images acquired at 3 slice thicknesses. Four radiologists subjectively evaluated visual assessment of the nodules on VS-CT.
Results:
ClearRead CT automatically detected 69.5% (66/95 nodules), 68.4% (65/95 nodules), and 70.5% (67/95 nodules) of all subsolid nodules in 3-, 2-, and 1-mm slices, respectively. The detection rate was higher for part-solid nodules than for pure ground-glass nodules at all slice thicknesses. In the visualization assessment on VS-CT, 3 nodules at each slice thickness (3.2%) were judged as invisible, while 26 of 29 (89.7%), 27 of 30 (90.0%), and 25 of 28 (89.3%) nodules, which were missed by computer-aided detection, were judged as visible in 3-, 2-, and 1-mm slices, respectively.
Conclusions:
The automatic detection rate of subsolid nodules by ClearRead CT was approximately 70% at all slice thicknesses. More than 95% of subsolid nodules were visualized on VS-CT, including nodules undetected by the automated software. Computed tomography acquisition at slices thinner than 3 mm did not confer any benefits.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...

