Intravasation complicating hysterosalpingo-foam sonography (HyFoSy) using ExEm® Foam
Jemma Ford1,2, Dana Hince3, Emmeline Lee1,2
1Western Ultrasound For Women, Perth, Western Australia, Australia.
Background:
Transvaginal hysterosalpingo-foam sonography (HyFoSy) assesses tubal patency in an outpatient setting and without ionising radiation, unlike traditional hysterosalpingography (HSG) under fluoroscopy. Like HSG, HyFoSy may be complicated by uterine intramural contrast leak, leading to venous intravasation. Intravasation of particulate contrast agents risks pulmonary or cerebral emboli.
Aims:
We aimed to assess the intravasation rate of HyFoSy using ExEm® Foam and association with endometrial thickness, ExEm® Foam volume, uterine length, adenomyosis severity, uterine morphology or pain score.
Methods:
An ethics-approved retrospective study on all HyFoSy examinations between 23 January 2018 and 27 October 2021 on sub-fertile patients, trying to conceive. Initial transvaginal sonography confirmed anatomy, uterine morphology, adenomyosis severity and endometrial thickness. Subspecialist radiologists performed HyFoSy with sonographer assistance. Intravasation was identified in real time but also checked for afterwards. Patients were asked to rate instillation pain/discomfort from one to ten immediately afterward.
Results:
Four hundred and thirty-six (n = 436) patients met inclusion criteria. Thirty (6.9%) experienced intravasation. Endometrial thickness and pain score were associated with intravasation. For every millimetre increase in endometrial thickness, the odds of intravasation decreased by 26% (P = 0.010). For every point increase on the pain scale, the odds of intravasation increased by 22% (P = 0.032). There was no evidence of an association between instilled ExEm® Foam volume or the other previously published parameters with intravasation.
Conclusion:
A 6.9% rate of intravasation was observed. Both endometrial thickness and pain score were significantly associated with intravasation. There was no evidence of an association between ExEm® Foam volume and intravasation.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies II: Ultrasonography
Urologic Endoscopic Procedure: Cystoscopic Examination