Related Experiment Video
Updated: Jul 30, 2025

09:03
A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
Published on: January 7, 2019
7.2K
Hollow core fiber Fabry-Perot interferometers with reduced sensitivity to temperature: erratum
Optics Letters
|May 15, 2023
Summary
A correction has been issued for a research article on hollow core fiber Fabry-Perot interferometers. The error identified does not alter the study's main conclusions regarding temperature sensitivity.
Area of Science:
- Optics and Photonics
- Fiber Optic Sensors
- Interferometry
Background:
- Hollow core fiber Fabry-Perot interferometers (HFPIs) are utilized for sensing applications.
- Minimizing temperature sensitivity in HFPIs is crucial for accurate measurements.
- Previous research explored methods to reduce temperature effects in HFPIs.
Purpose of the Study:
- To correct an error in the original publication of a study on HFPIs.
- To ensure accuracy in the scientific record concerning HFPI temperature sensitivity.
- To provide a corrected reference for future research in this field.
Main Methods:
- The study involved the fabrication and characterization of hollow core fiber Fabry-Perot interferometers.
- Specific techniques were employed to reduce the sensitivity of the interferometers to temperature fluctuations.
- A mathematical or experimental error in the original analysis has been identified and is being corrected.
Main Results:
- The original publication presented findings on HFPIs with reduced temperature sensitivity.
- A specific error within the original publication has been identified.
- The correction does not impact the fundamental conclusions drawn in the original study.
Conclusions:
- The core findings regarding the reduced temperature sensitivity of the hollow core fiber Fabry-Perot interferometers remain valid.
- The authors have issued a correction to maintain the integrity of the published research.
- This correction ensures the reliability of the study for the scientific community.
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
378
Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
378
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
1.4K
A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to...
According to Hooke's law, the vibrational frequency is directly proportional to...
1.4K
Temperature Measurement Sites
1.9K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.9K
Atomic Force Microscopy
3.5K
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
3.5K
Thermal Strain
2.0K
Thermal strain is a concept that arises when we consider how temperature changes affect structures. Unlike the conventional assumption that structures remain constant under load, real-world scenarios often involve temperature fluctuations that can significantly impact these structures. Consider a homogeneous rod with a uniform cross-section resting freely on a flat horizontal surface. If the rod's temperature increases, the rod elongates. This elongation is proportional to the temperature...
2.0K

