A Negative-Pressure Face-Mounted System Reduces Aerosol Spread during Endonasal Endoscopic Surgery
Edmond Jonathan Gandham1, Abhijit Goyal-Honavar1, Latif Rajesh Johnson2
1Department of Neurological Sciences, Section of Neurosurgery, Christian Medical College Hospital, Vellore, Tamil Nadu, India.
To reduce COVID-19 transmission during endonasal surgery, a negative-pressure mask was tested. This mask, along with suction and irrigation, effectively minimizes aerosol spread, offering additional safety during procedures.
Area of Science:
- Otolaryngology
- Infectious Disease Control
- Surgical Technology
Background:
- Endonasal surgeries pose a risk of COVID-19 transmission due to potential droplet and aerosol generation.
- Minimizing airborne particles during surgical procedures is crucial for patient and healthcare worker safety.
Purpose of the Study:
- To evaluate methods for reducing droplet and aerosol generation during endoscopic endonasal surgery.
- To assess the efficacy of a novel face-mounted negative-pressure mask in controlling airborne contaminants.
Main Methods:
- Droplet spread was assessed using fluorescence detection.
- Aerosol density (<10 µm) was measured with a photometric particle counter.
- A randomized controlled trial compared a negative-pressure mask group with a no-mask group, using continuous suction and irrigation.
Main Results:
- Aerosol density increased during sphenoid drilling in both groups when suction and irrigation were used.
- Interruption of suction and irrigation significantly increased aerosol density in the no-mask group.
- The negative-pressure mask demonstrated additional safety benefits, particularly when suction was inadvertently blocked.
Conclusions:
- Aerosol generation during endonasal drilling is a significant concern, especially during pandemics.
- Rigid suction and copious irrigation are effective in reducing aerosol spread.
- A negative-pressure mask offers supplementary protection against aerosol transmission in endonasal surgery.
More Related Videos
07:43Endoscopic Endonasal Trans-sphenoidal Approach: Minimally Invasive Surgery for Pituitary Adenomas
Published on: January 17, 2018
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...