Related Experiment Video
Updated: Jul 30, 2025

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
A Negative-Pressure Face-Mounted System Reduces Aerosol Spread during Endonasal Endoscopic Surgery
Edmond Jonathan Gandham1, Abhijit Goyal-Honavar1, Latif Rajesh Johnson2
1Department of Neurological Sciences, Section of Neurosurgery, Christian Medical College Hospital, Vellore, Tamil Nadu, India.
Abstract:
Purpose Due to the potential risk of COVID-19 transmission during endonasal surgery, we studied methods to reduce droplet and aerosol generation during these procedures. Methods Droplet spread was assessed using ultraviolet light and a camera that detected fluorescence in the operative field and surgeon's personal protective equipment. Density of aerosols sized <10 µm was measured using a photometric particle counter. We designed a face-mounted negative-pressure mask placed on the patients' face during endoscopic endonasal surgery. Sixteen patients were recruited between October 2020 and March 2021 and randomly assigned to the mask and no-mask groups. We compared droplet spread and aerosols generated in both groups, with copious irrigation and continuous suction during drilling forming the mainstay of surgical technique in all cases. Results Droplet contamination due to direct spillage of fluorescein from the syringe was noted in two patients. Aerosol density rose during sphenoid drilling in both groups, with no significant difference when continuous suction and irrigation were employed (1.27 times vs. 1.07 times the baseline, p = 0 .248 ). Aerosol density rose significantly when suction and irrigation were interrupted in the no-mask group (44.9 times vs. 1.2 times, p = 0 .028) , which was not seen when the mask was used. Conclusion Aerosol generation increases during drilling in endonasal procedures and is a concern during this pandemic. The use of a rigid suction close to the drill along with copious irrigation is effective in reducing aerosol spread. The use of a negative pressure mask provides additional safety when inadvertent blockage of suction and inadequate irrigation occur.
More Related Videos
07:43Endoscopic Endonasal Trans-sphenoidal Approach: Minimally Invasive Surgery for Pituitary Adenomas
Published on: January 17, 2018
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...