Related Experiment Video
Updated: Jul 30, 2025

Field-Based Thermal Physiology Assay: Cold Shock Recovery under Ambient Conditions
Published on: March 9, 2021
Temperature Monitoring of Two Different Thermal Boxes for the Transport of Biological Samples
Carlos Alexandre Curylofo Corsi1, Katia Carmen Gabriel Scarpelini2, Alan Vinicius Assunção-Luiz3
1Ribeirão Preto Medical School at University of São Paulo (FMRP/USP), Ribeirão Preto, SP, Brazil; Human Tissue Bank of Hospital das Clínicas, Ribeirão Preto Medical School at University of São Paulo (FMRP/USP), Ribeirão Preto, SP, Brazil.
Background:
According to the Resolutions of the Collegiate Board of Directors RDC No. 20/2014, 214/2018, and 707/2022, validation of the temperature of thermal boxes for the transport of biological samples must be based on standardized procedures and tested by the Tissue Banks, guaranteeing safety and quality. Therefore, they can be simulated. Our objective was to monitor and compare the temperature of 2 different coolers while transporting biological samples.
Methods:
The following items were packed in each of the 2 different thermal boxes (Box 1: Easy Path; Box 2: Safe Box Polyurethane Vegetal): 6 blood samples (30 mL), one bone tissue sample (200 g), 8 hard ice (Gelox, to keep the temperature <8ºC), and internal and external traceability "Time Stamp" sensors installed for measuring and storing temperature data in real-time. The monitored boxes were placed in the trunk of a bus that traveled an approximate distance of 630 km and were then placed in the trunk of a car, under direct sunlight, until they reached a temperature of 8ºC.
Results:
In Box 1, the internal temperature was maintained in the range of -7ºC to 8ºC for approximately 26 hours. In Box 2, the internal temperature was maintained in the range of -10ºC to 8ºC for approximately 98 hours and 40 minutes.
Conclusions:
We concluded that both coolers, under similar storage conditions, are suitable for transporting biological samples, with Box 2 maintaining the desired temperature for longer.
Related Concept Videos
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...