Delayed and Interrupted Ventilation with Excess Suctioning after Helping Babies Breathe with Congolese Birth

Jackie K Patterson1, Daniel Ishoso2, Joar Eilevstjønn3

  • 1Department of Pediatrics, University of North Carolina at Chapel Hill, 101 Manning Drive, CB 7596, Chapel Hill, NC 27514, USA.

There is a substantial gap in our understanding of resuscitation practices following Helping Babies Breathe (HBB) training. We sought to address this gap through an analysis of observed resuscitations following HBB 2nd edition training in the Democratic Republic of the Congo. This is a secondary analysis of a clinical trial evaluating the effect of resuscitation training and electronic heart rate monitoring on stillbirths. We included in-born, liveborn neonates ≥28 weeks gestation whose resuscitation care was directly observed and documented. For the 2592 births observed, providers dried/stimulated before suctioning in 97% of cases and suctioned before ventilating in 100%. Only 19.7% of newborns not breathing well by 60 s (s) after birth ever received ventilation. Providers initiated ventilation at a median 347 s (>five minutes) after birth; no cases were initiated within the Golden Minute. During 81 resuscitations involving ventilation, stimulation and suction both delayed and interrupted ventilation with a median 132 s spent drying/stimulating and 98 s suctioning. This study demonstrates that HBB-trained providers followed the correct order of resuscitation steps. Providers frequently failed to initiate ventilation. When ventilation was initiated, it was delayed and interrupted by stimulation and suctioning. Innovative strategies targeting early and continuous ventilation are needed to maximize the impact of HBB.

Related Concept Videos

Suctioning the Nasopharyngeal Airway01:29

Suctioning the Nasopharyngeal Airway

Nasopharyngeal suctioning is a procedure to remove secretions from the upper part of the respiratory tract that the patient cannot clear independently. It helps maintain airway patency and prevents complications such as aspiration pneumonia.
Equipment Required
559
Cardiopulmonary Resuscitation II: ACLS Airway Management01:22

Cardiopulmonary Resuscitation II: ACLS Airway Management

Airway management is a key skill in emergency and critical care settings, as maintaining a clear airway is essential for adequate oxygenation and ventilation.Head Tilt-Chin Lift TechniqueThe head tilt-chin lift maneuver is an essential technique primarily used in patients without suspected cervical spine injuries. To perform this maneuver, one hand is placed on the patient’s forehead, and gentle pressure is applied backward to tilt the head. The fingertips of the other hand are positioned...
26
Suctioning the Oropharyngeal Airway01:25

Suctioning the Oropharyngeal Airway

In preparing for oropharyngeal airway suctioning, a nurse must gather all necessary equipment, including a suction unit with tubing, a prepackaged suction kit, sterile gloves, water or saline for irrigation, a water-soluble lubricant, and additional personal protective equipment (such as a gown, mask, and goggles) to control infections.
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
276
Acute Respiratory Failure-V01:29

Acute Respiratory Failure-V

The treatment for acute respiratory failure varies based on factors like the underlying cause, overall health, and severity. A collaborative healthcare team is essential for early detection, often through arterial blood gas analysis. Identifying the cause is the primary goal, with treatment strategies adjusted for ventilation/perfusion (V/Q) mismatch, shunting, or diffusion impairment.
Ensure that patients are monitored continuously for their response to therapy, including changes in...
172
Mechanical Ventilation II: Invasive Ventilation01:23

Mechanical Ventilation II: Invasive Ventilation

Ventilators are essential medical equipment used to aid patients with respiratory difficulties. Their primary function is to assist or replace spontaneous breathing by providing mechanical ventilation. There are two general classes of mechanical ventilators: negative-pressure and positive-pressure ventilators.
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
189
Acute Respiratory Failure-III01:30

Acute Respiratory Failure-III

Hypercapnic respiratory failure, also known as Type 2 or ventilatory respiratory failure, is a severe condition characterized by the body's inability to effectively remove carbon dioxide (CO2) from the bloodstream. It leads to an arterial CO2 pressure (PaCO2) exceeding 45 mmHg and a blood pH above 7.35. This situation indicates that the body's ventilatory demand, or the ventilation needed to maintain normal PaCO2 levels, surpasses its supply or the maximum gas flow achievable without...
238