Related Experiment Video
Updated: Jul 30, 2025

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
Published on: February 4, 2018
Are single-peaked tuning curves tuned for speed rather than accuracy?
Movitz Lenninger1, Mikael Skoglund1, Pawel Andrzej Herman2
1Division of Information Science and Engineering, KTH Royal Institute of Technology, Stockholm, Sweden.
None:
According to the efficient coding hypothesis, sensory neurons are adapted to provide maximal information about the environment, given some biophysical constraints. In early visual areas, stimulus-induced modulations of neural activity (or tunings) are predominantly single-peaked. However, periodic tuning, as exhibited by grid cells, has been linked to a significant increase in decoding performance. Does this imply that the tuning curves in early visual areas are sub-optimal? We argue that the time scale at which neurons encode information is imperative to understand the advantages of single-peaked and periodic tuning curves, respectively. Here, we show that the possibility of catastrophic (large) errors creates a trade-off between decoding time and decoding ability. We investigate how decoding time and stimulus dimensionality affect the optimal shape of tuning curves for removing catastrophic errors. In particular, we focus on the spatial periods of the tuning curves for a class of circular tuning curves. We show an overall trend for minimal decoding time to increase with increasing Fisher information, implying a trade-off between accuracy and speed. This trade-off is reinforced whenever the stimulus dimensionality is high, or there is ongoing activity. Thus, given constraints on processing speed, we present normative arguments for the existence of the single-peaked tuning organization observed in early visual areas.
More Related Videos
Related Concept Videos
Problem-Solving: Tuning of a Guitar String
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...
Elevation of Intermediate Points on Vertical Curves
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...

