Related Experiment Video
Updated: Jul 30, 2025

Semi-Minimal Invasive Method to Induce Myocardial Infarction in Rats and the Assessment of Cardiac Function by an Isolated Working Heart System
Published on: June 11, 2020
Estimation of Left Ventricular Stroke Work for Rotary Left Ventricular Assist Devices
Eric L Wu1,2, Martin Maw3, Andrew F Stephens4,5
1From the Innovative Cardiovascular Engineering and Technology Laboratory (ICETLAB), Critical Care Research Group, The Prince Charles Hospital, Chermside, Queensland, Australia.
None:
Continuous monitoring of left ventricular stroke work (LVSW) may improve the medical management of patients with rotary left ventricular assist devices (LVAD). However, implantable pressure-volume sensors are limited by measurement drift and hemocompatibility. Instead, estimator algorithms derived from rotary LVAD signals may be a suitable alternative. An LVSW estimator algorithm was developed and evaluated in a range of in vitro and ex vivo cardiovascular conditions during full assist (closed aortic valve [AoV]) and partial assist (opening AoV) mode. For full assist, the LVSW estimator algorithm was based on LVAD flow, speed, and pump pressure head, whereas for partial assist, the LVSW estimator combined the full assist algorithm with an estimate of AoV flow. During full assist, the LVSW estimator demonstrated a good fit in vitro and ex vivo (R 2 : 0.97 and 0.86, respectively) with errors of ± 0.07 J. However, LVSW estimator performance was reduced during partial assist, with in vitro : R 2 : 0.88 and an error of ± 0.16 J and ex vivo : R 2 : 0.48 with errors of ± 0.11 J. Further investigations are required to improve the LVSW estimate with partial assist; however, this study demonstrated promising results for a continuous estimate of LVSW for rotary LVADs.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
08:09Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Regulation of Stroke Volume