Related Experiment Video
Updated: Jul 30, 2025

Tools for Surface Treatment of Silicon Planar Intracortical Microelectrodes
Published on: June 8, 2022
Surface modification of biodegradable Mg alloy by adapting µEDM capabilities with cryogenically-treated tool
Rahul Davis1, Abhishek Singh2, Kishore Debnath3
1Department of Mechanical Engineering, Vaugh Institute of Agricultural Engineering and Technology, Sam Higginbottom University of Agriculture, Technology and Sciences, Prayagraj, 211007 India.
Abstract:
Biomaterials are engineered to develop an interaction with living cells for therapeutic and diagnostic purposes. The last decade reported a tremendously rising shift in the requirement for miniaturized biomedical implants exhibiting high precision and comprising various biomaterials such as non-biodegradable titanium (Ti) alloys and biodegradable magnesium (Mg) alloys. The excellent mechanical properties and lightweight characteristics of Mg AZ91D alloy make it an emerging material for biomedical applications. In this regard, micro-electric discharge machining (µEDM) is an excellent method that can be used to make micro-components with high dimensional accuracy. In the present research, attempts were made to improve the µEDM capabilities by using cryogenically-treated copper (CTCTE) and brass tool electrodes (CTBTE) amid machining of biodegradable Mg AZ91D alloy, followed by their comparison with a pair of untreated copper (UCTE) and brass tool electrodes (UBTE) in terms of minimum machining-time and dimensional-irregularity. To investigate the possible modification on the surfaces achieved with minimum machining-time and dimensional-irregularity, the morphology, chemistry, micro-hardness, corrosion resistance, topography, and wettability of these surfaces were further examined. The surface produced by CTCTE exhibited the minimum surface micro-cracks and craters, acceptable recast layer thickness (2.6 µm), 17.45% improved micro-hardness, satisfactory corrosion resistance, adequate surface roughness (Ra: 1.08 µm), and suitable hydrophobic behavior (contact angle: 119°), confirming improved biodegradation rate. Additionally, a comparative analysis among the tool electrodes revealed that cryogenically-treated tool electrodes outperformed the untreated ones. CTCTE-induced modification on the Mg AZ91D alloy surface suggests its suitability in biodegradable medical implant applications.
More Related Videos
11:03Nanoscale Characterization of Liquid-Solid Interfaces by Coupling Cryo-Focused Ion Beam Milling with Scanning Electron Microscopy and Spectroscopy
Published on: July 14, 2022
14:49Direct and Indirect Culture Methods for Studying Biodegradable Implant Materials In Vitro
Published on: April 15, 2022