Related Experiment Video
Updated: Jul 30, 2025

Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Utilizing computed tomography volumetry for size matching prior to lung transplantation: a case series
Hailey M Shepherd1, Khashayar Farahnak1, M Shea Harrison1
1Department of Surgery, Washington University School of Medicine, St. Louis, MO, USA.
Background:
Appropriate size matching between donor and recipient is critical for successful pulmonary transplantation. Although surrogate measurements such as height and gender are often utilized to approximate predicted lung volume, these methods provide only a gross estimation with wide variability and poor predictive value.
Case Description:
A single center exploratory study was conducted in which four patients underwent lung transplantation (LT) with pre-operative computed tomography (CT) volumetry obtained in both the donor and recipient to facilitate decision making regarding organ size and suitability. In four cases in which CT volumetry was used, the lung volumes calculated using surrogate measurements significantly overestimated both donor and recipient lung volumes quantified by CT volumetric analysis. All recipients underwent successful LT without necessary graft downsizing.
Conclusions:
This is an initial report of prospectively utilizing CT volumetry as an adjunct to decision-making regarding suitability of donor lungs. In these cases, CT volumetry facilitated the confident acceptance of donor lungs that were initially predicted to be oversized based on other clinical measures.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography