Prediction of low DEXA T-scores by routine computed tomography body scans at different kilovoltage peaks
Mike Lin1, Lloyd Ridley2,3, Markus J Seibel1,3
1Department of Endocrinology and Metabolism, Concord Hospital, Sydney, New South Wales, Australia.
Introduction:
Previous studies have demonstrated positive correlations between computed tomography (CT) attenuation of lumbar spine vertebrae and their bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DEXA). However, these studies were performed using a standard 120 kilovoltage peak (kVp) setting. As radiation attenuation in mineralised tissues varies by the tube voltage applied, we determined the diagnostic accuracy of CT attenuation at identifying individuals with low BMD at different kVp settings.
Methods:
Single centre retrospective study of adults who had CT and DEXA scans within 6 months of each other. CT scans were performed at either 100 kVp, 120 kVp or dual energy (80 kVp/140 kVp). Attenuation was measured in axial cross-sections of L1-4 vertebrae and correlated with the results of DEXA. Receiver operated characteristic (ROC) curves were generated to determine diagnostic cut-off thresholds.
Results:
Analysis included 268 subjects (169 females; mean age: 70, range: 20-94 years). CT attenuation values at L1 or mean L1-4 correlated positively with DEXA-derived T-scores. At L1, the optimal Hounsfield units (HU) thresholds for predicting DEXA T-scores of -2.5 or less at 100 kVp, 120 kVp and dual-energy scans were <170, <128 and <164, with corresponding AUCs of 0.925, 0.814 and 0.743 respectively. For mean L1-4, the HU thresholds were <173, <134 and <151, with corresponding AUCs of 0.933, 0.824 and 0.707 respectively.
Conclusion:
CT attenuation thresholds differ depending on the tube voltage used. We provide voltage-specific, probability-optimised thresholds for the identification of persons likely to have low BMD on DEXA scanning.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...