Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
Published on: June 16, 2020
Assessment of the skin with 2D-shear wave elastography in the systemic scleroderma and its correlation with pulmonary
Ahmet Tanyeri1, Mehmet Burak Çildağ1
1Department of Radiology, Faculty of Medicine, Aydın Adnan Menderes University, Aydın, Turkey.
Purpose:
The purpose of this study was to assess the skin involvement in systemic scleroderma patients (SSc) with 2D-Shear Wave Elastography (2D-SWE) and to review the corelation between skin elasticity and pulmonary involvement.
Methods:
Thirty SSc patients and 30 controls were examined using 2D-SWE. The demographics matched both groups. B-mode ultrasound (US) and 2D-SWE assessed skin thickness and elastography from the ventral side of the right forearm in each subjective. ROC analysis determined optimal group separation cut-off values. A rheumatologist applied mRSS for SSc patients. US, mRSS, and pulmonary involvement correlations were reviewed.
Results:
US parameter values (skin thickness, median kPa, median m/s) were higher in the SSc patient group (1.78 ± 0.36 mm, 22.15 ± 16.26, 2.60 ± 0.82, respectively) compared to the control group (1.55 ± 0.2 mm, 7.45 ± 1.84, 1.56 ± 0.2, respectively, p < 0.05). When the optimal cut-off SWE values for separating groups was determined as 10.5 kPa and 1.87 m/s, the sensitivity was 93% and the specificity was 97%. Pearson's correlation analysis showed a strong positive correlation between mRSS and median SWE values (kPa, r = 0.626, p = 0.001; m/s, r = 0.638, p < 0.001). There was no correlation between pulmonary involvement of SSc patients with mRSS and US parameters.
Conclusion:
2D-SWE is a promising non-invasive method to evaluate skin involvement in SSc patient group. For pulmonary involvement we need more data with bigger patient groups.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...