Related Experiment Video
Updated: Jul 30, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
The association of denture wearing with reduced lung function and increased airflow limitation in 58-72 year old men
Niamh Kelly1, Kyra Gormley1, Dermot A Linden2
1Centre for Dentistry, School of Medicine Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, United Kingdom.
Objective:
To investigate the association between denture wearing and airflow limitation in men in Northern Ireland enrolled in the Prospective Epidemiological Study of Myocardial Infarction (PRIME) study.
Methods:
A case-control design was used to study partially dentate men. Cases were men aged 58-72 years who were confirmed as denture wearers. Controls were never denture wearers who were matched by age (± 1 month) and smoking habit to the cases. The men had a periodontal assessment and completed a questionnaire detailing their medical history, dental history and behaviours, social circumstances, demographic background and tobacco use. Physical examination and spirometry measurements of forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were also undertaken. Spirometry data for edentulous men who wore complete dentures were compared with that recorded for the partially dentate men studied.
Results:
There were 353 cases who were partially dentate and were confirmed denture wearers. They were matched for age and smoking habit to never denture wearer controls. The cases had an FEV1 that was on average 140 ml lower than the controls, p = 0.0013 and a 4% reduction in percent predicted FEV1, p = 0.0022. Application of the GOLD criteria indicated that 61 (17.3%) of the cases had moderate to severe airflow limitation compared with 33 (9.3%) of controls, p = 0.0051. Fully adjusted multivariable analysis showed that partially dentate men who were denture wearers were significantly more likely (p = 0.01) to have moderate to severe airflow reduction with an adjusted odds ratio (OR) of 2.37 (95% confidence intervals 1.23-4.55). In the 153 edentulous men studied moderate to severe airflow limitation was recorded in 44 (28.4%), which was significantly higher than in the partially dentate denture wearers (p = 0.017), and the men who had never worn a denture (p<0.0001).
Conclusion:
Denture wearing was associated with an increased risk of moderate to severe airflow limitation in the cohort of middle-aged Western European men studied.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-I: Introduction
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...

