Abstract:
The Bravo pH probe is a wireless capsule allowing remote quantification of gastroesophageal reflux. A 14-year-old male presented for Bravo probe placement. Following esophagogastroduodenoscopy, attachment of the Bravo probe was attempted. Immediately, the patient began coughing without oxygen desaturation. Repeat endoscopy did not reveal the probe within the esophagus or stomach. He was then intubated, and fluoroscopy demonstrated a foreign body within the bronchus intermedius. Rigid bronchoscopy was performed to retrieve the probe using optical forceps. This is the first case of pediatric inadvertent airway deployment requiring retrieval. We recommend endoscopic visualization of the delivery catheter entering the cricopharyngeus before Bravo probe deployment, then followed by repeat endoscopy to confirm position of the probe after attachment.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques