Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Second-Dimension Temperature Programming System for Comprehensive Two-Dimensional Gas Chromatography. Part 2:
Hei Yin J Chow1, Tadeusz Górecki1
1Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.
Abstract:
The second-dimension (2D) temperature programming system (2DTPS) for comprehensive two-dimensional gas chromatography (GC × GC) described in Part 1 was updated and tested with the time-of-flight mass spectrometer (TOFMS) and flow modulator. Addition of a real-time clock and remote port allowed the 2DTPS to be a truly standalone system to be used with any GC × GC instrument. GC × GC reproducibility with the 2DTPS was tested with thermal and flow modulation, coupled with the TOFMS and/or FID to demonstrate compatibility with all typical GC × GC setups. An improvement in the match factor, reverse match factor, and signal-to-noise ratio was found when performing 2D temperature programming. Within-day and day-to-day reproducibility of the 2DTPS for the 1D retention time (≤0.04 and ≤0.05%), 2D retention time (≤0.36 and ≤0.52%), and peak area (≤2.47 and ≤3.37%) were acceptable, while providing flexibility in 2D optimization and improved peak capacity.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...