Calibrating beam fluxes of a low-energy neutral atom beam facility
Jonathan Gasser1, André Galli1, Peter Wurz1
1University of Bern, Physics Institute, Space Research and Planetary Sciences, Sidlerstrasse 5, 3012 Bern, Switzerland.
Abstract:
Scientific detection and imaging instruments for low-energetic neutral atoms (ENA) onboard spacecraft require thorough pre-flight laboratory calibration against a well-characterized neutral atom beam source. To achieve this requirement, a dedicated test facility is available at the University of Bern, which is equipped with a powerful plasma ion source and an ion beam neutralization stage. Using surface neutralization, low-energy neutral atom beams of any desired gas species can be produced in the energy range from 3 keV down as low as 10 eV. As the efficiency of the neutralization stage is species and energy dependent, the neutralizer itself needs to be calibrated against an independent reference. We report on the calibration and characterization of this neutral atom beam source using our recently developed Absolute Beam Monitor (ABM) as a primary calibration standard. The ABM measures the absolute ENA flux independent of neutral species in the energy range from 10 eV to 3 keV. We obtain calibration factors of a few 100 cm-2 s-1 pA-1, depending on species at beam energies above about 100 eV, and a power-law decrease for energies below 100 eV. Furthermore, the energy loss of neutralized ions in the surface neutralizer is estimated from time-of-flight measurements using the ABM. The relative energy loss increases with ENA energy from low levels near zero up to 20%-35% at 3 keV, depending on atomic species. Having calibrated our neutral beam source allows for accurate calibration of ENA space instruments.
More Related Videos
08:31Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
09:49An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers
Published on: October 23, 2018
Related Concept Videos
Atomic Fluorescence Spectroscopy
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...