Related Experiment Video
Updated: Jul 29, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Oxygen storage module with physisorption technology for closed-circuit respirators
A M Swanger1, J E Fesmire1, R Fernando2
1NASA Kennedy Space Center, Cryogenics Test Laboratory, Kennedy Space Center, FL 32899 USA.
Abstract:
The new Cryogenic Flux Capacitor (CFC) technology employs nano-porous aerogel composites to store large quantities of fluid molecules in a physisorbed solid-state condition at moderate pressures and cryogenic temperatures. By its design architecture, a CFC device can be "charged" and "discharged" quickly and on demand according to standby/usage requirements. One of three main application areas is the CFC-Life for breathing air or oxygen supply to meet new demands in life support systems. Through the Liquid Oxygen Storage Module (LOXSM) Project, the National Institute for Occupational Safety and Health, and Cryogenics Test Laboratory have partnered to test the feasibility of applying the CFC technology to Closed-Circuit Escape Respirators (CCER), or respirators operating on the closed-circuit principle in general. The envisioned Cryogenic Oxygen Storage Module (COSM) is an innovative concept to store oxygen in solid-state form, according to physisorption processes at any cryogenic temperature, and deliver it as a gas using the CFC as the core storage element. Gaseous oxygen would be admitted into the breathing loop of the CCER by introducing heat into the storage module. Potentially replacing the gaseous or chemical based oxygen supply used in today's closed-circuit respirators, the COSM is a high capacity, conformal, small-size solution for future life support equipment of all kinds. In particular, are the CCER devices that must to be carried on the person, ready to be quickly deployed and used for escape in an emergency. Initial test data for physisorption of oxygen in aerogel materials and CFC core modules are presented. The basic operational parameters for charging and discharging are summarized through prototype testing of the cryogenic oxygen storage module.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Gas Exchange and Transport
Oxygen Transport in the Blood