Innovative approaches in cloud-point extraction

Radoslav Halko1, Ingrid Hagarová2, Vasil Andruch3

  • 1Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University Bratislava, Mlynská dolina, Ilkovičova 6, 842 15 Bratislava IV, Slovak Republic.

Summary

Cloud-point extraction (CPE) is a versatile pre-treatment method for concentrating analytes. Recent advances focus on innovative approaches, alternative media, and combined techniques for enhanced chemical analysis.

Related Concept Videos

Extraction: Advanced Methods00:56

Extraction: Advanced Methods

Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
497
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
1.9K
Extraction: Partition and Distribution Coefficients01:14

Extraction: Partition and Distribution Coefficients

The distribution law or Nernst's distribution law is the law that governs the distribution of a solute between two immiscible solvents. This law, also known as the partition law, states that if a solute is added to the mixture of two immiscible solvents at a constant temperature, the solute is distributed between the two solvents in such a way that the ratio of solute concentrations in the solvents remains constant at equilibrium.
For extracting a solute from an aqueous phase into an...
2.6K
Outliers and Influential Points01:08

Outliers and Influential Points

An outlier is an observation of data that does not fit the rest of the data. It is sometimes called an extreme value. When you graph an outlier, it will appear not to fit the pattern of the graph. Some outliers are due to mistakes (for example, writing down 50 instead of 500), while others may indicate that something unusual is happening. Outliers are present far from the least squares line in the vertical direction. They have large "errors," where the "error" or residual is the...
4.1K
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
593
Development of Analytical Methods01:21

Development of Analytical Methods

An analytical methodology can be divided into four sequential steps: technique, method, procedure, and protocol. A technique is a scientific principle that rationalizes a specific phenomenon through chemical measurements. Adapting a technique for analyzing a sample of interest is termed a method. The procedure outlines the directions for performing the analysis via an analytical method. The protocol is the detailed guidelines on the procedure, which should be strictly followed to obtain the...