Comparison of gas chromatographic techniques for the analysis of iodinated derivatives of aromatic amines
Nerea Lorenzo-Parodi1, Erich Leitner2, Torsten C Schmidt3,4,5
1Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany.
Abstract:
Some aromatic amines (AA) have been classified as carcinogens to humans. After entering the body, mainly through tobacco smoke, they can be detected in urine. Thus, their trace analysis as biomarkers in biofluids is of high relevance and can be achieved with gas chromatography (GC-MS), usually after derivatization. This study compares three gas chromatographic methods for the analysis of ten iodinated derivatives of AA: GC-MS in single-ion monitoring (SIM) mode with (1) electron ionization (GC-EI-MS) and (2) negative chemical ionization (GC-NCI-MS), and (3) GC-EI-MS/MS in multiple reaction monitoring (MRM) mode using electron ionization. All methods and most analytes showed good coefficients of determination (R2 > 0.99) for broad linear ranges covering three to five orders of magnitude in the picogram-per-liter to nanogram-per-liter range, with one and two exceptions for (1) and (2) respectively. Excellent limits of detection (LODs) of 9-50, 3.0-7.3, and 0.9-3.9 pg/L were observed for (1), (2), and (3) respectively, and good precision was achieved (intra-day repeatability < 15% and inter-day repeatability < 20% for most techniques and concentration levels). On average, recoveries between 80 and 104% were observed for all techniques. Urine samples of smokers and non-smokers were successfully analyzed, and p-toluidine and 2-chloroaniline could be found at significantly (α = 0.05) higher concentrations among smokers.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry of Amines
Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit...