Detection of impending reflex syncope by means of an integrated multisensor patch-type recorder
Antonella Groppelli1, Martina Rafanelli2, Giuseppe Dario Testa2
1IRCCS Istituto Auxologico Italiano, Faint & Fall programme, Cardiology Unit and Department of Cardiology, San Luca Hospital, Milan, Italy.
Abstract:
We assessed the capability of an integrated multisensory patch-type monitor (RootiRx®) in detecting episodes of reflex (pre)syncope induced by tilt table test (TTT). Firstly, we performed an intrapatient comparison of cuffless systolic blood pressure (SBP), R-R interval (RRI) and variability (power spectrum analysis) obtained by means of the RootiRx® with those obtained with conventional methods (CONV) with validated finger pressure devices at baseline in supine position and repeatedly during TTT in 32 patients affected by likely reflex syncope. Secondly, the LF/HF values obtained with RootiRx® during TTT were analyzed in 50 syncope patients. Compared with baseline supine recordings, during TTT a decrement of median SBP was observed with CONV (-53.5 mmHg) but not with RootiRx® ®(-1 mmHg). Conversely, RRI reduction (CONV: 102 ms; RootiRx®: 127 ms) and RRI Low Frequency/High Frequency powers ratio (LF/HF) increase (CONV: 1.6; RootiRx®: 2.5) were similar. The concordance was good for RRI (0.97 [95% CI 0.96-0.98]) and fair for LF/HF ratio (0.69 [95% CI 0.46-0.83]). During the first 5 min of TTT the LF/HF ratio was higher in patients who later developed syncope than in no-syncope patients. This ratio was significantly different among patients with syncope, presyncope or without symptoms at the time of syncope (p value = 0.02). In conclusion, cuffless RootiRx® was unable to detect rapid drops of SBP occurring during impending reflex syncope and thus cannot be used as a diagnostic tool for hypotensive syncope. On the other hand, RRI mean values and LF/HF power ratios obtained with RootiRx® were consistent with those simultaneously obtained using conventional methods.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:07Simultaneous Recordings of Cortical Local Field Potentials, Electrocardiogram, Electromyogram, and Breathing Rhythm from a Freely Moving Rat
Published on: April 2, 2018