Are Two- and Three-Dimensional Computed Tomographic Scan Measurements of Tibial Tubercle-Trochlear Groove Distance
Seow Hui Teo1, Teng Khiam Ong1, Azhar Mahmood Merican1
1Lembah Pantai, 50603 Kuala Lumpur, Malaysia National Orthopaedic Centre of Excellence for Research and Learning (NOCERAL), Department of Orthopaedic Surgery, Faculty of Medicine, Universiti Malaya.
Background:
Accurate planning for patellar instability correction is important in obtaining good post-operative outcome. The main challenge in the current two-dimensional (2-D) computed tomographic (CT) scans method is the difficulty in choosing reliable bony landmarks. This study aimed to compare the reliabilities between the 2-D and three-dimensional (3-D) methods of measuring tibial tubercle-trochlear groove (TT-TG) distance. We hypothesize that the proposed 3-D method will result in measurements with narrower error margin, providing higher reliability and accuracy.
Materials And Methods:
We traced CT scans of 106 knees with no patellofemoral pathology from 59 subjects from the database system and converted all 2-D images into 3-D models to determine the values for each parameter. We compared the intra- and interobserver reliability of each method using intraclass correlation (ICC) and Bland-Altman method.
Results:
The values of TT-TG measured by 2-D and 3-D methods were 16.1 ± 4.6 mm and 16.2 ± 4.2 mm, respectively. The ICC values of both methods were comparable (95% limits of agreement between the same observer: - 3.3 to 3.8 mm versus - 2.4 to 2.7 mm and different observers: - 4.3 to 4.9 mm versus - 3.9 to 2.7 mm), with 3-D method results in narrower limits of agreement.
Conclusion:
TT-TG measurement is reliable using the 2-D method without using advanced radiographic software. The 3-D method of measuring TT-TG provides measurement with narrower variation when compared with the 2-D method. However, both TT-TG distances' measurement methods in the current study were comparable as the variations are not significant.