Related Experiment Video
Updated: Jul 29, 2025

Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Comparing dual heat pulse methods with Péclet's number as universal switch to measure sap flow across a wide range
Yuchen Ma1, Ruiqi Ren1, Han Fu2
1College of Resources and Environmental Engineering, Ludong University, Yantai 264025, China.
Abstract:
Accurate determination of sap flow over a wide measurement range is important for assessing tree transpiration. However, this is difficult to achieve by using a single heat pulse method. Recent attempts have been made to combine multiple heat pulse methods and have successfully increased the sap flow measurement range. However, relative performance of different dual methods has not yet been addressed, and selection of the numerical threshold used to switch between methods has not been verified among different dual methods. This paper evaluates three different dual methods with respect to measurement range, precision and sources of uncertainty: (method 1) the heat ratio (HR) and compensation heat pulse method; (method 2) the HR and T-max method; and (method 3) the HR and double ratio method. Field experiments showed that methods 1, 2 with three needles and 3 compare well with the benchmark Sapflow+ method, having root mean square deviations of 4.7 cm h-1, 3.0 cm h-1 and 2.4 cm h-1, respectively. The three dual methods are equivalent in accuracy (P > 0.05). Moreover, all dual methods can satisfactorily measure reverse, low and medium heat pulse velocities. However, for high velocities (>100 cm h-1), the HR + T-max (method 2) performed better than the other methods. Another advantage is that this method has a three- instead of four-needle probe configuration, making it less error prone to probe misalignment and plant wounding. All dual methods in this study use the HR method for calculating low to medium flow and a different method for calculating high flow. The optimal threshold for switching from HR to another method is HR's maximum flow, which can be accurately determined from the Péclet number. This study therefore provides guidance for an optimal selection of methods for quantification of sap flow over a wide measurement range.
More Related Videos
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
07:34A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps
Published on: August 5, 2015
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pipe Flowrate Measurement: Problem Solving
Special considerations while measuring pulse
Voltammetric Techniques: Pulse Voltammetry