Related Experiment Video
Updated: Jul 29, 2025

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Influence of the ear temperature range on the measurement bias between an infrared thermometer and a reference probe
Kenza Laplace1, Eric Baccino2, Pierre-Antoine Peyron1
1Department of Forensic Medicine, University Hospital of Montpellier, Montpellier, France.
Abstract:
The aim of this study was to assess the influence of the post-mortem outer ear temperature (OET) on the measurement bias previously observed for short post-mortem intervals (PMI) between a commercially available infrared thermometer and a reference metal probe thermometer. To that end, 100 refrigerated bodies were added to our initial cohort to investigate lower OET. In contrast to our previous findings, a very good concordance was noted between both methods. There was still an overall underestimation of ear temperatures with the infrared thermometer, but the average bias was significantly reduced compared to that observed in the initial cohort (1.47 °C for the right ear and 1.32 °C for the left ear). Most importantly, this bias progressively decreased as the OET decreased, becoming negligible for OET lower than 20 °C. These results are in agreement with literature data regarding these temperature ranges. The discrepancy observed with our previous observations may be due to the technical characteristics of the infrared thermometers. The lower the temperatures measured, the more the measurements approach the lower limit of the measuring range of the device and tend to give constant values, resulting in a smaller underestimation of the measurements. Further research is needed to assess the interest of integrating in the already validated OET-based formulae a variable dependent on the temperature measured with the infrared thermometer, to eventually allow infrared thermometry to be used for PMI estimation in forensic practice.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...