Column selection considerations in compact capillary liquid chromatography
Samuel W Foster1, Elisabeth P Gates2, Paul A Peaden2
1Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States.
Abstract:
Recent years have seen significant advances in compact, portable capillary LC instrumentation. This study explores the performances of several commercially available columns within the pressure and flow limits of both the columns and one of these compact LC instruments. The commercially available compact capillary LC system with UV-absorbance detector used in this study is typically operated using columns in the 0.15-0.3 mm internal diameter (i.d.) range. Efficiency measurements (i.e., theoretical plates, N) for six columns with i.d.s in this range and of varying lengths and pressure limits, packed with stationary phases of different particle diameters and morphologies, were made using a mixture of standard alkylphenones. Kinetic plot comparisons between columns that vary by one (or more) of these parameters are described, along with calculated kinetic performance and Knox-Saleem limits. These theoretical performance descriptions provide insight into optimal operating conditions when using capillary LC systems. Based on kinetic plot evaluation of available capillary columns in the 0.2-0.3 mm i.d. range with a conservative upper pressure limit of 330 bar packed with superficially porous particles, a 25 cm column could generate ∼47,000 plates in 7.85 min when operated at 2.4 µL/min. For comparison, more robust 0.3 mm i.d. columns (packed with fully porous particles) that can be operated at higher pressures than can be provided by the pumping system (conservative pump upper pressure limit of 570 bar), a ∼20 cm column could generate nearly 40,000 plates in 5.9 min if operated at 6 µL/min. Across all capillary LC columns measured, higher pressure limits and shorter columns can provide the best throughput when considering both speed and efficiency.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Electrophoresis: Overview
There...
Principles Of Column Chromatography