Related Experiment Video
Updated: Jul 29, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Implementation of barcode medication administration (BMCA) technology on infusion pumps in the operating rooms
Manon Hogerwaard1, Muriël Stolk2, Liselotte van Dijk2
1Anesthesiology, Erasmus MC, Rotterdam, The Netherlands.
Background:
Medication administration errors (MAEs) are a major cause of morbidity and mortality. An updated barcode medication administration (BCMA) technology on infusion pumps is implemented in the operating rooms to automate double check at a syringe exchange.
Objective:
The aim of this mixed-methods before-and-after study is to understand the medication administrating process and assess the compliance with double check before and after implementation.
Methods:
Reported MAEs from 2019 to October 2021 were analysed and categorised to the three moments of medication administration: (1) bolus induction, (2) infusion pump start-up and (3) changing an empty syringe. Interviews were conducted to understand the medication administration process with functional resonance analysis method (FRAM). Double check was observed in the operating rooms before and after implementation. MAEs up to December 2022 were used for a run chart.
Results:
Analysis of MAEs showed that 70.9% occurred when changing an empty syringe. 90.0% of MAEs were deemed to be preventable with the use of the new BCMA technology. The FRAM model showed the extent of variation to double check by coworker or BCMA.Observations showed that the double check for pump start-up changed from 70.2% to 78.7% postimplementation (p=0.41). The BCMA double check contribution for pump start-up increased from 15.3% to 45.8% (p=0.0013). The double check for changing an empty syringe increased from 14.3% to 85.0% (p<0.0001) postimplementation. BCMA technology was new for changing an empty syringe and was used in 63.5% of administrations. MAEs for moments 2 and 3 were significantly reduced (p=0.0075) after implementation in the operating rooms and ICU.
Conclusion:
An updated BCMA technology contributes to a higher double check compliance and MAE reduction, especially when changing an empty syringe. BCMA technology has the potential to decrease MAEs if adherence is high enough.
Related Concept Videos
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Integrated Healthcare System
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...