Related Experiment Video
Updated: Jul 29, 2025

Author Spotlight: A Non-Invasive Tool to Assess and Differentiate Fat Patterns in Liver Using 3D Dixon MRI
Published on: October 20, 2023
Comparison of CT and Dixon MR Abdominal Adipose Tissue Quantification Using a Unified Computer-Assisted Software
Li-Yueh Hsu1, Zara Ali1, Hadi Bagheri1
1Department of Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Building 10, Room 1C370, 10 Center Drive, Bethesda, MA 20892, USA.
Purpose:
Reliable and objective measures of abdominal fat distribution across imaging modalities are essential for various clinical and research scenarios, such as assessing cardiometabolic disease risk due to obesity. We aimed to compare quantitative measures of subcutaneous (SAT) and visceral (VAT) adipose tissues in the abdomen between computed tomography (CT) and Dixon-based magnetic resonance (MR) images using a unified computer-assisted software framework.
Materials And Methods:
This study included 21 subjects who underwent abdominal CT and Dixon MR imaging on the same day. For each subject, two matched axial CT and fat-only MR images at the L2-L3 and the L4-L5 intervertebral levels were selected for fat quantification. For each image, an outer and an inner abdominal wall regions as well as SAT and VAT pixel masks were automatically generated by our software. The computer-generated results were then inspected and corrected by an expert reader.
Results:
There were excellent agreements for both abdominal wall segmentation and adipose tissue quantification between matched CT and MR images. Pearson coefficients were 0.97 for both outer and inner region segmentation, 0.99 for SAT, and 0.97 for VAT quantification. Bland-Altman analyses indicated minimum biases in all comparisons.
Conclusion:
We showed that abdominal adipose tissue can be reliably quantified from both CT and Dixon MR images using a unified computer-assisted software framework. This flexible framework has a simple-to-use workflow to measure SAT and VAT from both modalities to support various clinical research applications.