Related Experiment Video
Updated: Jul 29, 2025

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Detecting whether L1 or other lumbar levels would be excluded from DXA bone mineral density analysis during
Ronnie Sebro1,2, Cynthia De la Garza-Ramos3, Jeffrey J Peterson3
1Department of Radiology, Mayo Clinic, Jacksonville, FL, 32224, USA. Sebro.ronnie@mayo.edu.
Purpose:
One or more vertebrae are sometimes excluded from dual-energy X-ray absorptiometry (DXA) analysis if the bone mineral density (BMD) T-score estimates are not consistent with the other lumbar vertebrae BMD T-score estimates. The goal of this study was to build a machine learning framework to identify which vertebrae would be excluded from DXA analysis based on the computed tomography (CT) attenuation of the vertebrae.
Methods:
Retrospective review of 995 patients (69.0% female) aged 50 years or greater with CT scans of the abdomen/pelvis and DXA within 1 year of each other. Volumetric semi-automated segmentation of each vertebral body was performed using 3D-Slicer to obtain the CT attenuation of each vertebra. Radiomic features based on the CT attenuation of the lumbar vertebrae were created. The data were randomly split into training/validation (90%) and test datasets (10%). We used two multivariate machine learning models: a support vector machine (SVM) and a neural net (NN) to predict which vertebra(e) were excluded from DXA analysis.
Results:
L1, L2, L3, and L4 were excluded from DXA in 8.7% (87/995), 9.9% (99/995), 32.3% (321/995), and 42.6% (424/995) patients, respectively. The SVM had a higher area under the curve (AUC = 0.803) than the NN (AUC = 0.589) for predicting whether L1 would be excluded from DXA analysis (P = 0.015) in the test dataset. The SVM was better than the NN for predicting whether L2 (AUC = 0.757 compared to AUC = 0.478), L3 (AUC = 0.699 compared to AUC = 0.555), or L4 (AUC = 0.751 compared to AUC = 0.639) were excluded from DXA analysis.
Conclusions:
Machine learning algorithms could be used to identify which lumbar vertebrae would be excluded from DXA analysis and should not be used for opportunistic CT screening analysis. The SVM was better than the NN for identifying which lumbar vertebra should not be used for opportunistic CT screening analysis.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
07:56Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018