Related Experiment Video
Updated: Jul 29, 2025

Measuring and Mapping Patterns of Soil Erosion and Deposition Related to Soil Carbonate Concentrations Under Agricultural Management
Published on: September 12, 2017
Multi-temporal assessment of land surface temperatures as an indicator of land use/cover changes and climate
Ali Muslim Amiri1, Filiz Dadaser-Celik2
1Department of Environmental Engineering, Erciyes University, Kayseri, Turkey.
Abstract:
Land surface temperature (LST) is an important parameter that reflects land surface processes of water and energy balance and has been used in assessment of land use/cover changes. However, the use of LST in monitoring changes in non-urban areas such as agricultural areas and wetlands is still limited. In this study, we aim to determine the spatial and temporal changes in LST in a semi-arid agricultural basin in Turkey (Develi Basin), where land use/cover and climatic conditions showed considerable variability since 1980s. Irrigated agriculture have expanded in the basin since 1987, after the construction of a large irrigation project. The basin hosts an internationally important wetland, called the Sultan Marshes, affected negatively by irrigation expansion. The study covers a 39-year period from 1984 to 2022. Four Landsat Thematic Mapper (TM) images acquired in 1984, 1987, 2003, and 2007 and two Landsat 8 OLI/TIRS images acquired in 2014 and 2022 were used in the analyses. The land use/cover changes were evaluated based on Normalized Difference Vegetation Index (NDVI). LST was estimated through top-of-atmosphere brightness temperature from thermal bands of Landsat images. Climate variability from 2014 to 2022 was analyzed with statistical methods. The results indicated that Develi Basin faced both spatial and temporal land use/cover changes. The area covered with natural steppe vegetation and water bodies decreased in the basin. In contrast, the sparsely and densely vegetated soil covers, which mostly denote agricultural areas, increased. Changes in LST values were observed from 1984 to 2022 as a result of climatic factors and land use/cover changes. LST changes were variable across different land use/cover types; LST decreased in irrigated areas and increased in lakes that went dry over years. LST changes proved useful for evaluating land use/cover changes and climatic variations in agricultural basins.
More Related Videos
08:49Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
Related Concept Videos
Global Climate Change
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...