Related Experiment Video
Updated: Jul 29, 2025

Precision Measurements and Parametric Models of Vertebral Endplates
Published on: September 17, 2019
Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional
José Gerardo Fleiderman Valenzuela1, Juan Ignacio Cirillo Totera2, Diego Herreros Turkieltaub3
1Orthopedics and Traumatology Department, Clínica Universidad de Los Andes, Las Condes, Chile.
Background:
Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic computer-assisted tools have been developed, and one example of them is Surgimap.
Purpose:
To demonstrate that the sagittal balance measurements with Surgimap are equal and more time-efficient than with Agfa-Enterprise.
Material And Methods:
Retrospective-prospective study. Biased comparative analysis of radiographic measurements performed on two different occasions (96 h interval), between two spine surgeons using Surgimap and two radiologists using the traditional Cobb method (TCM) with the Agfa-Enterprise program in 36 full spine lateral X-ray, determining inter- and intra-observer reliability and the mean time required to obtain the measurements.
Results:
Measurements with both methods demonstrated an excellent intra-observer correlation (Surgimap: PCC 0.95 [0.85-0.99]; TCM: PCC 0.90 [0.81-0.99]). Inter-observer correlation also demonstrated an excellent relationship (PCC >0.95). Thoracic kyphosis (TK) demonstrated the lowest levels of inter-observer correlation (PCC: 0.75). The average time in seconds with TCM was 154.6, while with the Surgimap it was 41.8 s.
Conclusion:
Surgimap proved to be equally reliable and 3.5 times faster. Therefore, in consistency with the available literature, our results would allow us to promote the use of Surgimap as a clinical diagnostic tool considering precision and efficiency.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019