Related Experiment Video
Updated: Jul 29, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Decreased Utilization of Low Tidal Volume Ventilation Outside of the Intensive Care Unit as Compared to Inside
Luke Andrea1, Ari Moskowitz1, Jen-Ting Chen1
1Department of Critical Care Medicine, Montefiore Medical Center, Bronx, NY, USA.
Background: Investigations into the use of low tidal volume ventilation (LTVV) have been performed for patients in emergency departments (EDs) or intensive care units (ICUs). Practice differences between the ICU and non-ICU care areas have not been described. We hypothesized that the initial implementation of LTVV would be better inside ICUs than outside. Methods: This is a retrospective observational study of patients initiated on invasive mechanical ventilation (IMV) between January 1, 2016, and July 17, 2019. Initial recorded tidal volumes after intubation were used to compare the use of LTVV between care areas. Low tidal volume was considered 6.5 cc/kg of ideal body weight (IBW) or less. The primary outcome was the initiation of low tidal volume. Sensitivity analyses used a tidal volume of 8 cc/kg of IBW or less, and direct comparisons were performed between the ICU, ED, and wards. Results: There were 6392 initiations of IMV: 2217 (34.7%) in the ICU and 4175 (65.3%) outside. LTVV was more likely to be initiated in the ICU than outside (46.5% vs 34.2%; adjusted odds ratio [aOR] 0.62, 95% confidence interval [CI] 0.56-0.71, P < .01). The ICU also had more implementation when PaO2/FiO2 ratio was less than 300, (48.0% vs 34.6%; aOR 0.59, 95% CI 0.48-0.71, P < .01). When comparing individual locations, wards had lower odds of LTVV than the ICU (aOR 0.82, 95% CI 0.70-0.96, P = .02), the ED had lower odds than the ICU (aOR 0.55, 95% CI 0.48-0.63, P < .01), and the ED had lower odds than the wards (aOR 0.66, 95% CI 0.56-0.77, P < .01). Interpretation: Initial low tidal volumes were more likely to be initiated in the ICU than outside. This finding remained when examining only patients with a PaO2/FiO2 ratio less than 300. Care areas outside of the ICU do not employ LTVV as often as ICUs and are, therefore, a possible target for process improvement.
Background: Investigations into the use of low tidal volume ventilation (LTVV) have been performed for patients in emergency departments (EDs) or intensive care units (ICUs). Practice differences between the ICU and non-ICU care areas have not been described. We hypothesized that the initial implementation of LTVV would be better inside ICUs than outside. Methods: This is a retrospective observational study of patients initiated on invasive mechanical ventilation (IMV) between January 1, 2016, and July 17, 2019. Initial recorded tidal volumes after intubation were used to compare the use of LTVV between care areas. Low tidal volume was considered 6.5 cc/kg of ideal body weight (IBW) or less. The primary outcome was the initiation of low tidal volume. Sensitivity analyses used a tidal volume of 8 cc/kg of IBW or less, and direct comparisons were performed between the ICU, ED, and wards. Results: There were 6392 initiations of IMV: 2217 (34.7%) in the ICU and 4175 (65.3%) outside. LTVV was more likely to be initiated in the ICU than outside (46.5% vs 34.2%; adjusted odds ratio [aOR] 0.62, 95% confidence interval [CI] 0.56-0.71, P < .01). The ICU also had more implementation when PaO2/FiO2 ratio was less than 300, (48.0% vs 34.6%; aOR 0.59, 95% CI 0.48-0.71, P < .01). When comparing individual locations, wards had lower odds of LTVV than the ICU (aOR 0.82, 95% CI 0.70-0.96, P = .02), the ED had lower odds than the ICU (aOR 0.55, 95% CI 0.48-0.63, P < .01), and the ED had lower odds than the wards (aOR 0.66, 95% CI 0.56-0.77, P < .01). Interpretation: Initial low tidal volumes were more likely to be initiated in the ICU than outside. This finding remained when examining only patients with a PaO2/FiO2 ratio less than 300. Care areas outside of the ICU do not employ LTVV as often as ICUs and are, therefore, a possible target for process improvement.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Volumes and Capacities
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: