Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Thermodynamic characterization of interactions between environmental contaminants and room temperature ionic liquids
Emmanuel Varona-Torres1, Kevin A Schug1
1Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, TX, USA.
Abstract:
Understanding the thermodynamic interactions between an analyte and the sample phase is of paramount importance when choosing a co-solvent in headspace analysis. A sample phase - gas phase equilibrium partition coefficient (Kp) is used fundamentally to describe the distribution of the analyte between the two phases. Kp determinations by headspace gas chromatography (HS-GC) were acquired by two methods: vapor phase calibration (VPC) and phase ratio variation (PRV). Here, we demonstrated a pressurized - loop headspace system in conjunction with gas chromatography vacuum ultraviolet detection (HS-GC-VUV) to directly calculate the concentration of analytes in the gas phase from room temperature ionic liquids (RTILs) sample phases, using pseudo-absolute quantification (PAQ). PAQ, an attribute of VUV detection, allowed for quick determination of Kp and other thermodynamic properties, such as enthalpy (ΔH) and entropy (ΔS) of the system through the use of van't Hoff plots in the temperature range of 70-110 °C. The Kp determinations by PAQ were comparable to those obtained using the VPC method with percent difference ranging from ≤ 1-33%. Kp determinations were made for analytes (cyclohexane, benzene, octane, toluene, chlorobenzene, ethylbenzene, m-,p-, and o-xylene) at the varying temperatures (70-110 °C) using different RTILs (1-ethyl-3-methylimidazolium ethylsulfate ([EMIM][ESO4]), 1-ethyl-3-methylimidazolium diethylphosphate ([EMIM][DEP]), and tris(2-hydroxyethyl)methylammonium methylsulfate ([MTEOA][MeOSO3])) and (1-ethyl-3-methylimidazolium bis(trisfluoromethanesulfonyl)imide ([EMIM] [NTF2])). The results from the van't Hoff analysis revealed that [EMIM] cation-based RTILs exhibit strong solute-solvent interactions with analytes that have π- electrons.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...