Related Experiment Video
Updated: Jul 29, 2025

Visualization of Ambient Mass Spectrometry with the Use of Schlieren Photography
Published on: June 20, 2016
Ion Heating in Advanced Dielectric Barrier Discharge Ion Sources for Ambient Mass Spectrometry
Marcos Bouza1, Ezaz Ahmed2, Priscilla Rocío-Bautista1
1Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain.
Abstract:
Dielectric barrier discharges (DBD) are highly versatile plasma sources for forming ions at atmospheric pressure and near ambient temperatures for the rapid, direct, and sensitive analysis of molecules by mass spectrometry (MS). Ambient ion sources should ideally form intact ions, as in-source fragmentation can limit sensitivity, increase spectral complexity, and hinder interpretation. Here, we report the measurement of ion internal energy distributions for the four primary classes of DBD-based ion sources, specifically DBD ionization (DBDI), low-temperature plasma (LTP), flexible microtube plasma (FμTP), and active capillary plasma ionization (ACaPI), in addition to atmospheric pressure chemical ionization (APCI) using para-substituted benzylammonium thermometer ions. Surprisingly, the average extent of energy deposited by the use of ACaPI (90.6 kJ mol-1) was ∼40 kJ mol-1 lower than the other ion sources (DBDI, LTP, FμTP, and APCI; 130.2 to 134.1 kJ mol-1) in their conventional configurations, and slightly higher than electrospray ionization (80.8 kJ mol-1). The internal energy distributions did not depend strongly on the sample introduction conditions (i.e., the use of different solvents and sample vaporization temperatures) or the DBD plasma conditions (i.e., maximum applied voltage). By positioning the DBDI, LTP, and FμTP plasma jets on axis with the capillary entrance to the mass spectrometer, the extent of internal energy deposition could be reduced by up to 20 kJ mol-1, although at the expense of sensitivity. Overall, the use of an active capillary-based DBD can result in substantially less fragmentation of ions with labile bonds than alternate DBD sources and APCI with comparably high sensitivity.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
08:31Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Emission Spectroscopy: Lab